Sign In | Join Free | My chinalane.org |
|
Brand Name : HENGFENGYOU
Model Number : Electrical Switchgear
Certification : ISO IEC CB COC KEMA SNI SABS CCC
Place of Origin : China
MOQ : 1
Price : 200-20000/piece
Payment Terms : LC T/T
Supply Ability : 5000 piece/year
Delivery Time : 30 days
Packaging Details : wooden case package
Name : Electrical Switchgear
Feature : Superior performance, product safety, reliability, environmental protection
Brand : Power Distribution Transformer
Standard : CE,ISO,UL,SABS,3C, IEC60076-11 ISO9001 ISO14001 KEMA CE
MNS Low Voltage Electrical Distribution Box Drawer Out Switchgear Commercial Industrial
1.Product Description
Ac metal closed type shift switch cabinet is a three-phase ac 50HZ indoor device metal closed switch equipment.Is used in power plants, substation system rated voltage 35kV, rated maximum current 2000A maximum voltage no more than 40.5kV single bus or single bus sectionalized sets of distribution equipment.
This switch device meets the requirements of DL/ t404-91, IEC298, GB3906 and other standards, and has the functions of preventing wrong operation of circuit breaker, pushing and pulling handcart with load, grounding line, power transmission with grounding line and accidental charging interval (referred to as "five precautions")
Technical Parameters
No | Item | Unit | Parameter |
1 | Rated voltage | kV | 7.2kV, 12kV, 17.5kV, 24kV |
2 | Ratec frequency | Hz | 50/60 |
3 | Rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
4 | Branch busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
5 | Main busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
6 | 1 min power frequency withstand voltage(wet/dry) | kV | 38/48, 50/60/60/65 |
7 | Lightning impulse withstand voltage | kV | 75, 95/125 |
8 | Rated short circuit breaking current(peak) | kA | 40/50/63/80/100 |
9 | Short time withstand current(4s) | kA | 20/25/31.5/40 |
10 | Protection type | IP4X for housing |
No | Item | Unit | Parameter |
1 | Rated voltage | kV | 36kV, 40.5kV |
2 | Ratec frequency | Hz | 50/60 |
3 | Rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
4 | Branch busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
5 | Main busbar rated current | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 |
6 | 1 min power frequency withstand voltage(wet/dry) | kV | 70/95 |
7 | Lightning impulse withstand voltage | kV | 170/185 |
8 | Rated short circuit breaking current(peak) | kA | 20/25/31.5/40 |
9 | Short time withstand current(4s) | kA | 40/50/63/100 |
10 | Protection type | IP4X for housing |
3.Production details and workshop
4.Conditions of Use
1.The maximum ambient air temperature shall not exceed 40°C, and the minimum shall not below -25°C;
2.The altitude shall not exceed 1000m. If special customized transformers and low-voltage components are used, the altitude can reach 4,000m;
3.The vertical inclination is no more than 5°, and no violent vibration and impact;
4.The air humidity is not more than 90% (25°C);
5.No gas and conductive dust that will seriously affect the insulation of transformer,no explosion hazard and corrosion of electrical components;
6.Outdoor wind speed shall not exceed 35m/s;
7.If service conditions beyond the above, specially customized product is available.
FAQ:
1.Q: Are you manufacturer?
A: Yes, we are manufacturer. Our factory is in Qingdao City, Shandong Province.
2.Q: Can I get guarantee of products?
A: Yes, every product is 1 year quality warrantee under customer correct using the products.
3.Q: Do you have any Certificate?
A: Yes. Each of our unit has CE, 3C and KEMA certificate. If you need any other Certificate, we can help you to apply it.
4.Q: How can I pay you?
A: Pay by T/T and L/C is acceptable.
5.Q: What about the production?
A: In general, it take 2~6weeks and it depend on the different style.
![]() |
MNS Low Voltage Electrical Distribution Box Drawer Out Switchgear Commercial Industrial Images |